CT-Systems (Wavetek) 3000B Service Monitor Mods and Notes


The zipped file linked to here (323KB) contains information and schematics concerning possible modifications to your CT-Systems / Wavetek Model 3000B or 3000S Service Monitor.

Modifications as follows are addressed:

1 Modulation Meter Peak Reading (standard is AVERAGE)

2 WIDE RESOLUTION is extended to 200 Khz P-P instead of the standard 36 khz P-P (lets you monitor and measure FM Broadcast band and TV Aural Carriers) Requires bridging each of 4 resistors with an additional 2700 ohm resistor (on the IF Board) and resetting the WIDE GAIN pot on the module to present the same RF Level reading on the scope presentation as the NARROW setting displays, while looking at the same carrier.

3 Remove De-emphasis network so the meter and front panel jack will yield wide band fm composite modulation up to beyond 20 KHZ

4 Meter scale switch -- to extend the FM Modulation Meter circuit to display a X10 scaled reading (18 KHZ is normal) -- Modulation mod lets you switch the scale to 180 khz meter reading.

Also included are some technical notes regarding the Model 3000B/3000S, as well as an informative repair history item.

All credit and thanks for the data go to Frank Hertel of Newman-Kees Measurements in Evansville, IN. Frank could use some assistance in return.. he's in dire need of an IC as described in item number 4 of the tech notes. Its number in the manual is 17100-70-1800, and it's an IMI #70350-04B. If you have any information that would help him acquire this IC, please let me know, thanks.

If you need a manual for the 3000B, please check here.


AA4DF's Yard Sale